pump system
Pump head calculator
Flow rate q (gpm):    

Static head sh (ft)    

Inside diameter d (in)    

Pipe or tube length L (ft)    

Velocity (ft/s) = 5.1

Pipe friction head per 100 ft of pipe (ft/100 ft) = 30.9

Pipe friction head (ft) = 2.5

Pump head h (ft) = 2.5    (static head + friction head)

more info?

1. You can check these results by doing your own calculations. To check the values calculated for pipe friction see the Cameron Hydraulic data book pipe friction tables
The formula for velocity is v (ft/s) = 0.4085 x q(gpm) / (d(in))2
2. The liquid is assumed to be water. Pipes or tubes are issumed to be smooth such as steel or PVC.
3. Match the pump head calculated with the vendor's rated head for a flow rate close to your required flow rate.
see this article The strange behavior of liquids. May 31, 2018
4. If the suction line is longer than 3-4 ft, add this length to the length of the pipe.
5. The friction loss calculation is done using the Swamee-Jain formula.
6. This app is intended to be used for educational purposes, the author takes no responsibility for the use of these results.
J. Chaurette June 6, 2018